4-1
CHAPTER 4
OPERATION
4.1 PRECAUTIONS
Do not turn off the main power or pull the power cord from the wall outlet without first
turning off the POWER switch located on the back of the unit.
The Imagesetter employs only low voltage power supplies. However, hazardous
voltages are present in the motor driver and in the AC input wiring. Reasonable safety
precautions should be used to avoid electrical shock. Turn the unit off before replacing
the media supply roll or servicing any component.
Circuits installed on the thermal print head are composed of CMOS ICs. Care must be
taken during operation and service to avoid damage from static electricity. When
replacing the print head, conductive mats and grounding straps should be used to
prevent damage due to electrostatic discharges (ESD).
The print head may become dirty even after short periods of operation. Clean the print
head every time a new roll of media is installed. Turn the power off and clean the print
head with the alcohol-saturated pads supplied with the unit. Allow time for the alcohol
to evaporate before turning the power on again.
Never attempt to operate the unit without media moving across the print head. Such a
condition may cause severe damage and void the warranty.
4.2 CONTROL PANEL KEYPAD FUNCTIONS
To access control panel selections, the Imagesetter must be taken off line by toggling the
ON LINE key once. The green ONLINE light will go off, and the "OFF LINE" message
will be displayed. The layout of the control panel is shown in Fig. 4.1.
4.2.1 FRONT PANEL INDICATORS
There are two LED indicators (ON LINE and STATUS) on the panel. Both indicators
are bi-color (green and red).
When the ON LINE indicator is lit green, the Imagesetter is in On Line state and ready to
accept data; when it goes off, the Imagesetter is in OFF LINE state and can go to the
MENU or ITEM mode to change parameters.
Vedere la pagina 0
1 2 3 4 5 6 ... 35 36

Sommario

Pagina 1

4-1CHAPTER 4OPERATION4.1 PRECAUTIONS Do not turn off the main power or pull the power cord from the wall outlet without firstturning off the POWE

Pagina 2

4-10ASCII PRINT: This test pattern prints 40 lines of 96 ASCII characters across the media.The resolution of the plot is indicated on the left side of

Pagina 3 - CONTROL PANEL KEYPAD

4-11PLATEN ACCURACY: This test checks the stepping accuracy of the Imagesetter andprints the nominal distance lines with inch annotations. A sample

Pagina 4

4-12NIB TEST: This test checks whether any failed nib of the print head exists. In additionto the leading and tail mark lines, a vertical line of a h

Pagina 5

4-13FIG. 4.5.b400 x 800 DPI NIB TEST PATTERN

Pagina 6 - ITEMs of SYSTEM Menu

4-144.3.3 ADVANCED TESTSOPEN-LOOP CHECK: This test is seldom needed by the user; however, it is providedas a diagnosis and coarse adjustment tool in c

Pagina 7 - ITEMs of JOB menu

4-15PLOT CALIBRATION: Usually the platen accuracy has been adjusted within thespecification at the production facility before the delivery of the Imag

Pagina 8 - ITEMs of IMAGE menu

4-16CONTRAST TEST: After entering this test mode, the PARM+ or PARM- key can beused to select the range of contrast settings to be tested. To run t

Pagina 9

4-174.4 ERROR MESSAGESThe following Error Messages may appear on the VF Display. There are three categoriesof error messages. The error messages alo

Pagina 10

04/05/995-1CHAPTER 5INTERFACE5.1 GENERAL DESCRIPTIONThe Imagesetter can be connected to a variety of data sources using the "Versateccompatible&

Pagina 11

04/05/995-2All data, control and status signals are connected to the Imagesetter via the male 37-pinD-series subminiature connector (J1) at the rear

Pagina 12

4-2If the Imagesetter detects any error, the STATUS indicator will be lit red. An errormessage will also be shown on the VF display. See Section 4.4

Pagina 13 - FIG. 4.5.b

04/05/995-3SIGNAL PIN RETURN PIN SIGNAL NAME MNEMONIC1 20 Input Bit 1 (LSB) IN012 21 Input Bit 2 IN023 22 Input Bit 3 IN034 23 Input Bit 4 IN045 24 In

Pagina 14

04/05/995-4SIGNALMNEMONICSIGNALNAMEACTIVELEVELOPERATIONPRINT PRINT HIGH This line selects either print orplot operation.High: PRINT; Low: PLOT TABLE

Pagina 15

04/05/995-5SIGNALMNEMONICSIGNALNAMEACTIVELEVELOPERATIONONLIN ON-LINE LOW A low level indicates the unit is poweredon, set to ON-LINE, and the interfac

Pagina 16

04/05/995-6Fig. 5.3 shows typical configurations for the interface receivers and drivers. The interfacecable should be limited to a maximum length o

Pagina 17

04/05/995-75.2 PLOT MODEThe Imagesetter uses the raster scan method of plotting. One horizontal line (scan),consisting of a single row of dots, is

Pagina 18 - BYTE-PARALLEL DATA

04/05/995-8Fig. 5.4DATA TRANSFER TIMINGFig. 5.5CONTROL SIGNAL TIMINGBYTE 1 BYTE 2 BYTE 3 1 uS (Note 2)READYBUSY (Note 1)NOTES:1. Data may change when

Pagina 19 - 04/05/99

04/05/995-95.3 PRINT MODEThe Imagesetter is equipped with a character generator, which converts ASCII-codedcharacters to pre-programmed plot patterns

Pagina 20

04/05/995-105.4 DRIVER CONSIDERATIONSThe following are a summary of the issues to be considered when preparing softwaredrivers to interface with the I

Pagina 21

04/05/995-11will be processed and all other remote commands will be cleared. - If CLEAR occurs, the input buffer is cleared, any simultaneous RLTER

Pagina 22

04/05/996-1CHAPTER 6REMOTE ESCAPE SEQUENCE COMMAND CONTROL6.1 ESCAPE SEQUENCE COMMANDS In order to print an image data file at a desired configurati

Pagina 23 - DIFFERENTIAL

4-3Fig 4.1CONTROL PANEL KEYPADSTATUSON LINEON LINEMENU CUT/PARM+FEED/PARM-ENTERITEMIM GER ON L INEA

Pagina 24

04/05/996-2COMMAND BYTECharacter FunctionF Imagersetter Resolution SelectionH Hysteresis ControlI Inverse Image SettingL Scan Line LengthM Mirror Imag

Pagina 25 - CONTROL SIGNAL TIMING

04/05/996-3PP = 0001 400 x 400 dpiPP = 0003 400 x 800 dpiHYSTERESIS CONTROL SELECTION (H)This command enables or disables the hysteresis control. The

Pagina 26

04/05/996-4SPEED CONTROL (S)This command selects the output speed of the Imagesetter. The calling sequence is:[ESC] [S] 00 02 PPwhere the corresponde

Pagina 27

04/05/996-5[ESC] [X] 00 00Note that, as other escape sequence commands, the function of this command is appliedonly to the EOT of the immediate follow

Pagina 28

04/05/996-6Disable FF & EOT Reset (>)This command causes the Imagesetter not to reset escape sequence command functions ifa form-feed (FF) or a

Pagina 29

04/05/996-7to the original configuration (before the change caused by those escape commands)after the PLOT mode job of desirable functions is complete

Pagina 30

04/05/996-8(the Imagesetter moves one inch now; for next image file, itÕs still 400x400 image,but a normal EOT)· Set the Imagesetter in PLOT mode·

Pagina 31

4-44.2.3 MENU AND ITEM MODESTable 4.1 shows the menus and menu items available with the basic Imagesetterconfiguration. A detailed description of me

Pagina 32

4-54.2.4 PARAMETER SELECTIONITEMs for each of the three menus (SYSTEM, JOB, and IMAGE) and theirPARAMETER selections are listed in Table 4.2, 4.3 an

Pagina 33

4-6ITEM PARAMETER DEFINITIONScan Line - Either Full or Partial; Fixed for each model as: 18Ó- 900 bytes per line @400dpi 24Ó- 1184 bytes per line

Pagina 34

4-7ITEM PARAMETER DEFINITIONImager Resolution - H: 400 dpi V: 400 dpi- H: 400 dpi V: 800 dpiH (horizontal): along the print headV (vertical): the

Pagina 35

4-8ITEM PARAMETER DEFINITIONContrast Level -35% to +20%(5% increment)Adjust image contrast levelImager Speed 0.1 to 0.5 ips (Note 1)Show Transport Pa

Pagina 36

4-94.3.2 BASIC TESTSCHECKERBOARD: This test pattern displays checkerboard squares along the media for4 inches at 400x400 dpi and for 2 inches at 400x